AUTO ALIGNING TIME CLOCK INSTRUCTIONS
Model 2650
12 888.479.7264
Prior to removing old ribbon, press button 4 & hold for approximately 6 seconds
to park ribbon in center position.
Unplug time clock.
To remove old ribbon, pull two white clips towards you & simultaneously lift
ribbon cartridge, pull straight up using tab located on top of cartridge.
Remove new ribbon cartridge from packaging & turn the manual ribbon advance
knob clockwise to straighten ribbon.
Holding tab install ribbon cartridge into print carriage, making certain to
lower the ribbon in front of the ribbon guide rst, then make certain
retaining pins are within clips (see diagram).
Gently push down cartridge until it snaps into carriage while turning the manual
ribbon advance knob clockwise.
Turn manual ribbon advance knob clockwise a few rotations to ensure ribbon is
positioned correctly in front of print head.
Replace the cover & lock unit.
Feed a time card through unit to test print quality.
REPLACING RIBBON CARTRIDGE
For optimum performance, the ribbon cartridge should be replaced every 6 months.
1
2
3
4
5
6
7
8
9
If time clock prints incomplete characters, the ribbon is not fully installed over print
head. If time clock prints lines that become increasingly light, the cartridge is not
fully snapped into the holder. Reinstall ribbon cartridge, following steps 1-7 until a
complete & consistent time card prints.